top of page

ESD: Fiberwood™ Double Deflection Grille

The Fiberwood™ Double Deflection Grille features a standard or separate OBD ( On-Board Diameter ) airflow control valve. ESD is ideal for commercial, residential, restaurant, parking lot, and restroom applications. The product is tested according to ANSI/ASHRAE Standard 70-06 and has obtained BS476-CLASS 0 fire resistance rating. Please contact us for all certifications and test reports.

Standard Construction

  • Material: 6mm Extruded Fiberwood
  • Minimum Size: 100 mm * 100 mm
  • Maximum Size (single piece): 1220 mm * 1220 mm
  • Oversized construction available with muillions and/or duct channels
  • You can order and install the same size to replace your old aluminum/iron/wooden double-leaf doors.
  • Height: 50mm (If <50mm, Model: ESE )

Options

  • Short leaves in front, long leaves behind (ESD-V) (Figure 1)
  • Longer leaves in front, shorter leaves behind (ESD-H) (Figures 2 and 4)
  • Opposed Blade Damper (+D)
  • Filter frame (+FF)
  • Insect screen (+IS)
  • Square to round adaptor (+SR)
  • Hinged Type (Model: ESBSD)

How to order

  • Ex. Matte white fiber double leaf - 25mm edge - longer leaf in front - OBD included - face measurement 800*300
  • Code: ESD-H/25/+D/BASE/800*300/Matt White
32 mm Frame (32 sides)
25 mm Frame (25 sides)
20 mm Frame (20 sides)
12 mm Frame (4 sides)
16 mm Frame (5-point side)
Other frame sizes (contact us)

FRAME

No additional accessories required
Opposed Blade Damper (O.B.D.)
Plenum Box (G.I. Steel)
Perforated Plate (+PP)

ACCESSORIES

Longer leaves in front (ASD-H)
Shorter leaves in front (ASD-V)

BLADE POSITION (RECTANGULAR)

Border Calculation Formula

    border Neck Tianhua left a roar Wind throat Neck height
    20mm B-28mm B-20mm B-25mm 50mm
    25mm B-40mm B-30mm B-35mm 50mm
    32mm B-52mm B-40mm B-45mm 50mm
    • B = Base Size (Meter)
    • Assuming a 25mm edge is chosen, the face value is 300mm.
    • Neck gauge = 260mm
    • Ceiling height = 270mm
    • Air vent hole = 265mm

Other borders/methods

    • A frame thickness of less than 20mm is not recommended.
    • Narrower bezels will have less impact on appearance and rigidity, thus reducing the risk of installation distortion.
    • Narrower frames require more precise ceiling openings.

Frequently Asked Questions

    • Can the neck be thinned?
    • No, the neck depth of double-leafed plants must be at least 50mm. If it is less than 50mm, consider using single-leafed plants (ASE), which only need to be 25~32mm.
bottom of page