ISO 9001:2015 - QUALITY MANAGEMENT SYSTEMS
Certificate No.: Q1902
Supply of air outlets and air inlets (Diffuser, Grille, Register, Slot, Louvre, Volume control damper, Fire damper, Air filter and Duct) for HVAC systemState Rich Air Conditioning Products Limited is pleased to announce the achievement of the ISO 9001:2015 Quality Management Systems certification. The company previously earned certification under ISO 9001:2008 and has been audited and registered annually by ACI Registrars.
ASHRAE 70-2006 STANDARD "METHOD OF TESTING FOR RATING THE PERFORMANCE OF AIR OUTLETS AND INLETS."
On All Types Of Cycnix Air Diffusers And Grilles
Test Report No.: 105109837 CRT-001a etc.,The lastest test was held by Intertek Testing Laboratory in the United States on Aug, 2022. The test results include Static Pressure, Area Factor, Throw and Sound Power Level. Acoustical data was obtained employing a Bruel & Kjaer Pulse Digital Frequency Analyzer. The reference sound source used for this test was a calibrated Bruel & Kjaer Type 4204, which conforms to the above standard.
FIRE DAMPER - BS 476: PART 20: 1987 FIRE RESISTANCE TEST
On an Un-insulated Vertical Mild Steel Fire Damper
Test Report No.: R21C07-AThe lastest test was held by RED Hong Kong Main Laboratory in April, 2021. The Hong Kong Accreditation Service (HKAS) has accredited this laboratory (HOKLAS 091-TEST) under Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory activities as listed in the HOKLAS directory of accreditation laboratories.
AIR FILTER TEST - ANSI/ASHRAE STANDARD 52.2-2017 "Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle Size"
On Aluminum Air Filter (Dust Type Filter)
Test Report No.: 23-554-2The test was held by Blue Heaven Technologies in the United States on Nov, 2023. The test result indicate that our Aluminum Air Filter meets the requirement of E&M equipment comply list.
ROHS - RESTRICTION OF THE USE OF CERTAIN HAZARDOUS SUBSTANCES IN ELECTRICAL AND ELECTRONIC EQUIPMENT, 2011/65/EU LAST AMENDED BY (EU) 2015/863
On Aluminum and Fiberwood Air Outlets and Inlets
Test Report No.: 0154132992a2 002The test was held by TÜV Rheinland in Shanghai, China. The test result states that there are no detection of lead (Pb), cadmium (Cd), mercury (Hg), hexavalent chromium (Cr6+), polybrominated biphenyl (PBB) and polybrominated diphenyl ether (PBDE) on the Diffusers and Grilles.
ASTM C518-15 - THERMAL CONDUCTIVITY & THERMAL RESISTANCE
On Raw Fiberwood Material
Test Report No.: SZIN1709013408PSThe lastest test was carried out by SGS-CSTC Standards Technical Services Co., Ltd ShangHai Branch on Oct, 2017. The test results helps our clients to understand the differences between Aluminum and Fiberwood.
"ANTI-DROP" INSULATION MATERIAL ON METALLIC AIR DIFFUSER
Use as insulation of air diffusers for ventilating system base on BS:476 Part 6& 7 Class "0"
Test Report No.: AJFS1712011224FF of 2.1.2018The F.S.D. have no objection in principle to the use of "Anti-Drop" insulation material on metallic air diffuser for ventilating systems in Hong Kong subject to compliance the requirements of Part XI of the FSD Circular Letter No. 4/96 and according to the following test report conducted by SGS-CTI Standards Technical Service Co. Ltd., Anji Branch.
MILL TEST CERTIFICATE REPORT (MTC) ON OUR METAL PRODUCTS
MTC report is available upon request.
Standard: EN10204 3.1 / EN10204 3.2 / ASTM B209-07 / 5052 H32 etc.,A Mill Certificate (or Mill Test Certificate, MTC) is a quality assurance document issued by a manufacturer to certify the chemical and mechanical properties of raw materials, such as metals, plastics, or other industrial products. It ensures compliance with international standards and customer specifications.
Certifications